Tuesday, 17 January 2012

Dial2Start Programming Issue

Hi Everyone,

I have come across an issue with the programming of the Administrator List. I just installed a unit at a local airstrip where the owner wanted the unit to control his runway lights and rotating beacon.

An issue arose when I tried to program the Administrator list so that he would get a confirmation text when either of the relays were activated. The unit will send a confirmation text only to the first two positions on the Administrator list.

I was programming it like this #PWD123456#TEL01=1234567890
This is how the command code was written in the literature I received with the control boards. It has since been updated and there was a difference in the way the position code is depicted.
Above it is shown as TEL01 whereas it should be TEL1.

I hope this helps you if you have had an issue getting the unit to acknowledge your attempt to populate the Administrator List.